B: baryta weight to be added to V (m3) of mud to increase the density of d1 to d2 (kg)
Br: barytage rate (kg / min)
Ci: number of strokes corresponding to the internal volume of the liner Vi
Ca: number of strokes corresponding to the total annular volume Va
Cd: number of strokes corresponding to the annular volume of the overdraft Vd
d1: initial density of the mud (drilling mud density)
d2: intermediate mud density in case of heavier multistage
dr: mud density required to put the well under control
deql: mud density balancing the pore pressure
deqv: effective density of the mud in the annulus.
dg: density (or density in kg / liter) of gas measured against water
dfrac: fracture density
Gfrac: fracture gradient of the fragile formation (bar / m)
Gp: pressure gradient expressed in bar / m
G: volume of the measured surface came after the pit closure (liter)
N: number of strokes corresponding to the drilling speed (strokes / min)
Nr: number of strokes corresponding to the control flow (strokes / min)
PAdm: maximum allowable pressure at the top of the annular space, closed well, corresponding to fracturing the fragile period (Bars)
Pamax: head pressure of the annular space to the arrival of the surface of gas cap (Bars)
PapG: static pressure at the top of the annular space full of gas (Bars)
Pcl: pressure drop control flow measured in the circuit (Bars)
Pc2: pressure drop control flow with mud d2 measured in the circuit (Bars)
Pcr: pressure drop control flow with mud dr measured in the circuit (Bars)
Pfond: pressure on the well bottom (Bars)
Ppores: fluid formation pressure (Bars)
Ph: hydrostatic pressure (Bars)
Pfrac: brittle fracture pressure at the point (Bars)
PR: traffic or discharge pressure (Bars)
PR1: Initial pressure control traffic flow with the density mud d1 (Bars)
PR2: Initial pressure control traffic flow with the density mud d2 (Bars)
RRP: final pressure control traffic flow with mud dr (Bars)
Ps: pressure the fragile point the shoe in general (Bars)
Psmax: maximum pressure sensitive period (Bars)
Pt1: settled pressure at the top of the stems, closed well after coming, with mud d1 (Bars)
Pa1: stabilized wellhead pressure of the annular space, closed well after coming, with mud d1 (Bars)
Q: drilling flow (liter / min)
Qr: control flow (liters / min)
Qu: Unit actual pump flow (liters / pulse)
Van: total volume of the annular space (m3)
V: internal volume of the drill string (m3)
Vd: discovered annulus volume (m3)
V: total volume of sludge including weighing in the trays (m3)
L: measured depth of the well (m)
Z: vertical depth of the well (m)
Ls: Fragile points measured depth (m)
Zs: Fragile vertical depth mark (m)
Heff: theoretical height of the effluent at the bottom (m)
Pha: hydrostatic pressure in the annulus (Bars)
Phi: hydrostatic pressure from within the liner (Bars)